Portable Conductivity Meter/EC Meter
EC110B/EC210E/EC310F/EC310T/EC510T
EC110B Portable Conductivity Meter
GENERAL FEATURES
* LCD display screen, 3.5 inches.
* Reset feature automatically resumes all settings back to factory default options.
* Auto-power off feature effectively extends the battery service life.
* IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
* Cell constant is settable
* Manual temperature compensation ensures accurate results.
PRODUCT SPECIFICATIONS
Model | EC110B | |
Parameters | EC | |
Conductivity | Range | 0.00 μS/cm to 100 mS/cm |
Resolution | 0.01 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 25 ºC | |
Measurement | Reading Mode | Continuous |
Reading Prompts | Reading, Stable | |
Temp. Compensation | MTC | |
Inputs | Conductivity | 5-pin aviation connector |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 80×255×35 mm | |
Weight | 400g (0.88 lb) |
EC210E Portable Conductivity Meter
GENERAL FEATURES
* LCD display screen, 3.5 inches.
* Multi-reading feature allows auto-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Auto-hold feature senses and locks the measurement endpoint.
* Data capacity of up to 200 sets for each parameter.
* Auto-power off feature effectively extends the battery service life.
* Reset feature automatically resumes all settings back to factory default options.
* IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
** 1 point calibration with Standard Recognition.
* Cell constant is settable
* Automatic/manual temperature compensation ensures accurate results.
PRODUCT SPECIFICATIONS
Parameters | EC/Temp.(TDS) | |
Conductivity | Range | 0.00 μS/cm to 200 mS/cm |
Resolution | 0.01 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 25 ºC | |
Calibration Points | Up to 1 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0%FS | |
Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.2 | |
Measurement | Reading Mode | Auto Read, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 200 results each |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 80×255×35 mm | |
Weight | 400g (0.88 lb) |
EC310F Portable Conductivity Meter
GENERAL FEATURES
* LCD display screen, 3.5 inches.
* Multi-reading feature allows auto-read, timed-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Auto-hold feature senses and locks the measurement endpoint.
* Data capacity of up to 500 sets for each parameter (GLP-compliant).
* Support for USB communication.
* Auto-power off feature effectively extends the battery service life.
* Reset feature automatically resumes all settings back to factory default options.
* IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.
* 1-3 points calibration with Standard Recognition.
* Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.
* Temperature compensation type (none, linear, pure water).
PRODUCT SPECIFICATIONS
Model | EC310F | |
Parameters | EC/Temp.(Resistivity/TDS/Sal.) | |
Conductivity | Range | 0.000 μS/cm to 500 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 20, 25 ºC | |
Calibration Points | Up to 3 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω·cm~20.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±1.0% FS | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L minimum, various with range selection | |
Accuracy | ±1.0%FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.01% | |
Accuracy | ±0.2% | |
Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.2 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 500 results each |
GLP Features | Yes | |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Outputs | USB | PC, printer |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 90×255×40 mm&400g (0.88 lb) |
EC310T Portable Conductivity Meter
GENERAL FEATURES
* LCD display screen, 3.5 inches.
* Multi-reading feature allows auto-read, timed-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Auto-hold feature senses and locks the measurement endpoint.
* Data capacity of up to 500 sets for each parameter (GLP-compliant).
* Support for USB communication.
* Auto-power off feature effectively extends the battery service life.
* Reset feature automatically resumes all settings back to factory default options.
* IP65 waterproof. The portable meter is suitable for fields measurements and out
door measurements.
* 1-3 points calibration with Standard Recognition.
* Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.
* Temperature compensation type (none, linear, pure water).
PRODUCT SPECIFICATIONS
Model | EC310T | |
Parameters | EC/Temp.(Resistivity/TDS/Sal.) | |
Conductivity | Range | 0.000 μS/cm to 1000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±1.0% FS | |
Reference Temperature | 20, 25 ºC | |
Calibration Points | Up to 3 | |
Standard Recognition | 84μS/cm, 1413μS/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω ·cm~20.00 MΩ ·cm |
Resolution | 0.01Ω ·cm minimum, | |
Accuracy | ±1.0% FS | |
TDS | Range | 0.00mg/L~300g/L |
Resolution | 0.01mg/L(0.001mg/L) minimum, 3 significant digits | |
Accuracy | ±1.0%FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.01% | |
Accuracy | ±0.2% | |
Temperature | Range | -5 to 110 ºC, 23 to 230 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.2 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Outputs | USB | PC, printer |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 90 x 255 x 40 mm&500g (1.1 lb) |
EC510T Portable Conductivity Meter
GENERAL FEATURES
* Color High contrast LCD touchscreen, 4.3 inches.
* Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.
* Multi-reading feature allows auto-read, timed-read and continuous-read.
* Automatic/Manual temperature compensation ensures accurate results.
* Auto-hold feature senses and locks the measurement endpoint.
* Data Storage 1000 sets for each parameter (GLP-compliant).
* Data analysis feature helps user review, compare and recalculate results.
* Support for USB communication.
* Auto-power off feature effectively extends the battery service life.
* Reset feature automatically resumes all settings back to factory default options.
* IP65 waterproof, suitable for fields measurements and out door measurements.
** 1-5 points calibration automatically recognizes the standard solutions.
* Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
* Temperature compensation type (none, linear, pure water).
PRODUCT SPECIFICATIONS
Parameters | EC/Resistivity/TDS /Sal./Temp. | |
Conductivity | Range | 0.000 μS/cm to 3000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000mg/L~1000g/L |
Resolution | 0.001mg/L minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Range | (0.00~8.00)% |
Resolution | 0.01% | |
Accuracy | ±0.1% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs | Conductivity with Temp. Probe | 5-pin aviation connector |
Outputs | USB | USB 2.0 flash memory device, PC, scanner |
Bluetooth | printer | |
Display options | Backlight | Yes |
Auto Shutdown | 300, 600, 1200, 1800, 3600 sec., off | |
IP Rating | IP65 | |
Date and Time | Yes | |
General | Power | Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output |
Dimensions | 90×255×40 mm&500g (1.1 lb) |