Titrator Ti-20
Automatic Potential Titrator Ti-40/Ti-50
Karl Fischer Coulometer KFT-20V/KFT-40C
Karl Fischer Moisture Titrator KFT-40VC
Ti-20 Titrator
GENERAL FEATURES
² LCD display screen.
² Support the following titration modes: SET (Preset Endpoint Titration) and MAT (Manual titration).
² Stirrer is included.
² Glass burette can be used for volume measurement (prepared by user).
PRODUCT SPECIFICATIONS
Model | Ti-20 | |
Measuring Unit | Range | (0~±1400) mV, (0~14.00)pH |
Resolutions | 1mV, 0.01pH | |
Accuracy | pH: ±0.03pH mV: ±5mV | |
Fluctuation | ±0.01pH /3h | |
General | Power Supply | AC Adapter, 200-240 VAC input |
Dimension (mm)& Weight (kg) | 300×235×100; 3 |
Ti-40 Automatic Potential Titrator
GENERAL FEATURES
² LCD display screen and smart guide system.
² Titration methods, curves and results are displayed in detail.
² Replaceable burette with high-accuracy (10 ml or 20 ml selectable).
² Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).
² pH calibration and measurement are supported.
² Store up to 50 titration data sets (GLP-compliant) and 1 latest set of titration curve.
² Data can be easily transferred to printer via RS-232 communication interface..
² Titrator can be controlled by computer via USB or RS-232 communication interface.
PRODUCT SPECIFICATIONS
Model | Ti-40 | |
Burette | Repeatability | 0.2% |
Accuracy | 10ml Burette: ±0.025ml; 20ml Burette: ±0.035ml | |
Resolution | 10ml Burette: 1/10000; 20ml Burette: 2/10000 | |
Mechanical Unit | Resolution | 1/30000 |
Measuring Unit | Range | (-1800.0~1800.0) mv, (0.00~14.00)pH |
Resolutions | 0.1mV, 0.01pH | |
Accuracy | pH: ±0.01pH mv: ±0.03%FS | |
Fluctuation | (±0.3mV±1bit) /3h | |
Temp. Compensation | Range | (-5.0~105.0) ℃ |
Resolutions | 0.1 ℃ | |
Accuracy | ±0.3 ℃ | |
General | Power Supply | AC Adapter, 100-240V AC input, DC24V output |
Dimension (mm)& Weight (kg) | 340×400×400; 8 |
Ti-50 Automatic Potential Titrator
GENERAL FEATURES
² 7” colorful touchscreen and smart guide system.
² Titration methods, curves and results are displayed in detail.
² 1 extra burette driver can be installed (optional).
² Replaceable burette with high-accuracy (10 ml or 20 ml selectable).
² Intelligent operation system provides features including user management, method management, electrode management, titrant management, data management, etc.
² Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).
² pH calibration and measurement are supported.
² Up to 100 user-defined methods and 10 user-defined shortcuts.
² Auto calculation with pre-defined formula.
² Store up to 200 titration data sets (GLP-compliant).
² Data analysis feature helps user review, compare and recalculate results.
² Data can be easily transferred to printer via RS-232 communication interface..
² Titrator can be controlled by computer via USB or RS-232 communication interface.
² Automatic sampler is supported.
PRODUCT SPECIFICATIONS
Model | Ti-50 | |
Burette | Repeatability | 0.20% |
Accuracy | 10ml Burette: ±0.025ml; 20ml Burette: ±0.035ml | |
Resolution | 10ml Burette: 1/20000; 20ml Burette: 1/10000 | |
Mechanical Unit | Resolution | 1/30000 |
Measuring Unit | Range | (-1999.0~1999.0) mv, (0.00~14.00)pH |
Resolutions | 0.1mV, 0.01pH | |
Accuracy | pH: ±0.01pH mv: ±0.03%FS | |
Fluctuation | (±0.3mV±1bit) /3h | |
Temp. Compensation | Range | (-5.0~105.0) ℃ |
Resolutions | 0.1 ℃ | |
Accuracy | ±0.3 ℃ | |
General | Power Supply | AC Adapter, 100-240V AC input, DC24V output |
Dimension (mm)& Weight (kg) | 340×400×400; 10 |
KFT-20V Karl Fischer Coulometer
GENERAL FEATURES
² LCD display screen.
² Generator cell with diaphragm.
² Selectable units including μg, mg, %, mg/L, g/L, etc.
² Settable parameters, including measurement unit, polarization current, generator current, endpoint potential, stop criterion and etc.
² Data can be stored and easily transferred to printer via RS-232 communication interface.
² Reset feature automatically resumes all settings back to factory default options.
PRODUCT SPECIFICATIONS
Model | KFT-20V | |
Coulometric Ttration | Range | 10ug~20mg |
Polarization Current Accuracy | ±0.2μA | |
Working Current | 10mA, 20 mA, 50 mA, 100 mA | |
Working Current Accuracy | 0.5% | |
Accuracy | ± (5%+3) μg | |
Repeatability | ±3% | |
General | Power Supply | AC Adapter, 200-240 VAC input |
Dimension (mm) & Weight (kg) | 300×235×100; 3 |
KFT-40C Karl Fischer Titrator
GENERAL FEATURES
² LCD display screen.
² Support KF Titration Mode and Titer Detection Mode.
² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
² Selectable units including mg, mg/L, %, ppm, etc.
² Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
² Store up to 200 titration data sets (GLP-compliant).
² Data can be easily transferred to printer via RS-232 commnication interface.
² Reset feature automatically resumes all settings back to factory default options.
PRODUCT SPECIFICATIONS
Model | KFT-40C | |
Volumetric Titration | Range | 0.1mg~250mg |
Polarization Current Accuracy | 0.1mg | |
Working Current | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ±0.5% | |
General | Power Supply | AC Adapter, 100-240 V AC input |
Dimension (mm) & Weight (kg) | 340×400×400; 10 |
KFT-40VC Karl Fischer Moisture Titrator
GENERAL FEATURES
² LCD display screen.
² Titration methods, curves and results are displayed in detail.
² Volumetric KF Titration and Coulometric KF Titration are supported.
² Data analysis feature helps user review and compare results.
² Data can be easily transferred to printer via RS-232 communication interface.
² Reset feature automatically resumes all settings back to factory default options.
Volumetric Karl Fischer Titration
² Support KF Titration Mode and Titer Detection Mode.
² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
² Automatic/manual background drift correction ensures accurate results.
² Selectable units including mg, mg/L, %, ppm, etc.
² Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.
² Store up to 200 titration data sets (GLP-compliant).
Coulometric Karl Fischer Titration
² Generator cell with diaphragm.
² Automatic/manual background drift correction ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L, μg/mL, etc.
² Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.
² Store up to 200 titration data sets (GLP-compliant).
PRODUCT SPECIFICATIONS
Model | KFT-40VC | |
Volumetric Titration | Range | (0.1mg~250)mg |
Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ±0.5% | |
Coulometric Titration | Range | 10μg~20mg |
Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
Working Current | 1, 1.86, 5, 10μg (H2O)/S | |
Accuracy | ± (5%+3) μg | |
Repeatability | RSD of 100μg sample measurement result ≤3% | |
General | Power Supply | AC Adapter, 100-240 V AC input |
Dimension (mm) & Weight (kg) | 340×400×400; 10 |