Ti-20 Titrator

GENERAL FEATURES

² LCD display screen.

² Support the following titration modes: SET (Preset Endpoint Titration) and MAT (Manual titration).

² Stirrer is included.

² Glass burette can be used for volume measurement (prepared by user).

PRODUCT SPECIFICATIONS

Model

Ti-20

Measuring Unit

Range

(0~±1400) mV, (0~14.00)pH

Resolutions

1mV, 0.01pH

Accuracy

pH: ±0.03pH mV: ±5mV

Fluctuation

±0.01pH /3h

General

Power Supply

AC Adapter, 200-240 VAC input

Dimension (mm)& Weight (kg)

300×235×100; 3


Ti-40 Automatic Potential Titrator

GENERAL FEATURES

² LCD display screen and smart guide system.

² Titration methods, curves and results are displayed in detail.

² Replaceable burette with high-accuracy (10 ml or 20 ml selectable).

² Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).

² pH calibration and measurement are supported.

² Store up to 50 titration data sets (GLP-compliant) and 1 latest set of titration curve.

² Data can be easily transferred to printer via RS-232 communication interface..

² Titrator can be controlled by computer via USB or RS-232 communication interface.

PRODUCT SPECIFICATIONS

Model

Ti-40

Burette

Repeatability

0.2%

Accuracy

10ml Burette: ±0.025ml;

20ml Burette: ±0.035ml

Resolution

10ml Burette: 1/10000;

20ml Burette: 2/10000

Mechanical Unit

Resolution

1/30000

Measuring Unit

Range

(-1800.0~1800.0) mv, (0.00~14.00)pH

Resolutions

0.1mV, 0.01pH

Accuracy

pH: ±0.01pH mv: ±0.03%FS

Fluctuation

(±0.3mV±1bit) /3h

Temp. Compensation

Range

(-5.0~105.0)  

Resolutions

0.1

Accuracy

±0.3

General

Power Supply

AC Adapter, 100-240V AC input, DC24V output

Dimension (mm)& Weight (kg)

340×400×400; 8

Ti-50 Automatic Potential Titrator

GENERAL FEATURES

² 7” colorful touchscreen and smart guide system.

² Titration methods, curves and results are displayed in detail.

² 1 extra burette driver can be installed (optional).

² Replaceable burette with high-accuracy (10 ml or 20 ml selectable).

² Intelligent operation system provides features including user management, method management, electrode management, titrant management, data management, etc.

² Support the following titration modes: DET (dynamic equivalence point titration), MET (monotone equivalence point titration), SET (Preset Endpoint Titration) and MAT (manual titration).

² pH calibration and measurement are supported.

² Up to 100 user-defined methods and 10 user-defined shortcuts.

² Auto calculation with pre-defined formula.

² Store up to 200 titration data sets (GLP-compliant).

² Data analysis feature helps user review, compare and recalculate results.

² Data can be easily transferred to printer via RS-232 communication interface..

² Titrator can be controlled by computer via USB or RS-232 communication interface.

² Automatic sampler is supported.


PRODUCT SPECIFICATIONS

Model

Ti-50

Burette

Repeatability

0.20%

Accuracy

10ml Burette: ±0.025ml; 20ml Burette: ±0.035ml

Resolution

10ml Burette: 1/20000; 20ml Burette: 1/10000

Mechanical Unit

Resolution

1/30000

Measuring Unit

Range

(-1999.0~1999.0) mv, (0.00~14.00)pH

Resolutions

0.1mV, 0.01pH

Accuracy

pH: ±0.01pH mv: ±0.03%FS

Fluctuation

(±0.3mV±1bit) /3h

Temp. Compensation

Range

(-5.0~105.0)  

Resolutions

0.1

Accuracy

±0.3

General

Power Supply

AC Adapter, 100-240V AC input, DC24V output

Dimension (mm)& Weight (kg)

340×400×400; 10

KFT-20V Karl Fischer Coulometer

GENERAL FEATURES

² LCD display screen.

² Generator cell with diaphragm.

² Selectable units including μg, mg, %, mg/L, g/L, etc.

² Settable parameters, including measurement unit, polarization current, generator current, endpoint potential, stop criterion and etc.

² Data can be stored and easily transferred to printer via RS-232 communication interface.

² Reset feature automatically resumes all settings back to factory default options.

PRODUCT SPECIFICATIONS

Model

KFT-20V

Coulometric Ttration

Range

10ug~20mg

Polarization Current Accuracy

±0.2μA

Working Current

10mA, 20 mA, 50 mA, 100 mA

Working Current Accuracy

0.5%

Accuracy

± (5%+3) μg

Repeatability

±3%

General

Power Supply

AC Adapter200-240 VAC input

Dimension (mm) & Weight (kg)

300×235×100; 3

KFT-40C Karl Fischer Titrator

GENERAL FEATURES

² LCD display screen.

² Support KF Titration Mode and Titer Detection Mode.

² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.

² Selectable units including mg, mg/L, %, ppm, etc.

² Settable parameters, including measurement unit, polarization current, stirring rate, titration ratestop volume, endpoint potential, stop criterion and etc.

² Store up to 200 titration data sets (GLP-compliant).

² Data can be easily transferred to printer via RS-232 commnication interface.

² Reset feature automatically resumes all settings back to factory default options.

PRODUCT SPECIFICATIONS

Model

KFT-40C

Volumetric Titration

Range

0.1mg~250mg

Polarization Current Accuracy

0.1mg

Working Current

1μA±0.2μA; 50μA±10μA

Repeatability

±0.5%

General

Power Supply

AC Adapter100-240 V AC input

Dimension (mm) & Weight (kg)

340×400×400; 10

KFT-40VC Karl Fischer Moisture Titrator

GENERAL FEATURES

² LCD display screen.

² Titration methods, curves and results are displayed in detail.

² Volumetric KF Titration and Coulometric KF Titration are supported.

² Data analysis feature helps user review and compare results.

² Data can be easily transferred to printer via RS-232 communication interface.

² Reset feature automatically resumes all settings back to factory default options.

Volumetric Karl Fischer Titration

² Support KF Titration Mode and Titer Detection Mode.

² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.

² Automatic/manual background drift correction ensures accurate results.

² Selectable units including mg, mg/L, %, ppm, etc.

² Settable parameters, including measurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion and etc.

² Store up to 200 titration data sets (GLP-compliant).

Coulometric Karl Fischer Titration

² Generator cell with diaphragm.

² Automatic/manual background drift correction ensures accurate results.

² Selectable units including μg, mg, %, ppm, mg/L, μg/mL, etc.

² Settable parameters, including measurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion and etc.

² Store up to 200 titration data sets (GLP-compliant).

PRODUCT SPECIFICATIONS

Model

KFT-40VC

Volumetric Titration

Range

(0.1mg~250)mg

Polarization Current Accuracy

1μA±0.2μA; 50μA±10μA

Repeatability

±0.5%

Coulometric Titration

Range

10μg~20mg

Polarization Current Accuracy

1μA±0.2μA; 50μA±10μA

Working Current

1, 1.86, 5, 10μg (H2O)/S

Accuracy

± (5%+3) μg

Repeatability

RSD of 100μg sample measurement result ≤3%

General

Power Supply

AC Adapter100-240 V AC input

Dimension (mm) & Weight (kg)

340×400×400; 10