DVT Series Touch screen Viscometer
LVDV-1T/RVDV-1T/HADV-1T/HBDV-1T/LVDV-2T/RVDV-2T/HADV-2T/HBDV-2T
Perfect integration of touch-screen technology, fast, accurate, easy to measure viscosity. Stepless debugging,
can measure super high viscosity of the sample. 5-inch color touch screen can be comprehensive, visual display of a variety of parameters and working conditions.
It has many advantages, such as many measuring parameters, rich display content, convenient operation, intuitive reading, high measuring precision, stable rotational speed, strong anti-interference performance, showing the curve of shear rate and viscosity, and so on.
Main features:
1. adopt ARM technology, built-in Linux system. The operation interface is simple and clear, through the creation of test program and data analysis, the viscosity test is carried out quickly and conveniently.
2. the viscosity test value is accurate : each measuring range is automatically calibrated by a computer , the precision is high , and the error is small ;
3. display is rich: in addition to viscosity (dynamic viscosity and kinematic viscosity), there are also temperature, shear rate, shear stress, measurement value as a percentage of the full range value
(graphic display, range overflow alarm, automatic scanning, Maximum measurement range, date, time and so on under current rotor speed combination. Show kinematic viscosity when density is known.
4. complete functions: timing measurement, self-built 30 groups of test programs, access to 30 groups of measurement data, real-time display of viscosity curves, printing data and curves;
5. front level: level adjustment is intuitionistic and convenient;
6. stepless speed regulation:
RV1T series: 0.3-100 rpm, a total of 998 rotational speeds
RV2T series: 0.1-200rpm, 2000 revolutions
7. showing the curve of shear rate versus viscosity : the range of shear rate can be set , and displayed on the computer in real time ;Curve of time - to - viscosity can also be displayed
8. optional Pt100 temperature probe: wide temperature range, ranging from -20 ℃ to 300 ℃, and measuring precision 0.1 ℃;
9. Optional accessories rich: R1 rotor, temperature sensor, viscometer special thermostat bath, thermostat cup, printer, standard viscosity sample (standard silicone oil), etc.;
The measurable range is very large, ranging from 100 to 320 million MPA.
Widely used in paint, paint, cosmetics, ink, pulp, food, oil, starch, solvent adhesive, latex, biochemical products and other high viscosity industries.
Detailed technical parameters:
Model | LVDV-1T | LVDV-2T |
Control / display mode | 5-inch color touch screen | |
Speed(r/min) | 0.3–100 infinitely variable speed , a total of 998 speed options | 0.1–200 infinitely variable speed , a total of 2000 speed options |
Measuring range | Rotor 1- 4: 10-2M mPa.s ULR: 1-1K Rotor 18: 3 - 10K Rotor 25: 480 - 1.60M Rotor 31: 30 - 100K Rotor 34: 20 - 200K | Rotor 1-4: 10–6M mPa.s ULR: 1-6K Rotor 18: 1.5 - 300K Rotor 25: 240 – 4.8M Rotor 31: 15 - 300K Rotor 34: 30 - 600K |
Rotor | L1 - L4 (Standard) Enhanced ultra-low viscosity adapter ULR (optional) Small sample adapters (rotors 18,25,31,34)(optional)) | |
Sample dosage | Rotor 1- 4: 300 - 400ml ULR: 21ml Rotor 18:7ml Rotor 25: 9ml Rotor 31: 10.5ml Rotor 34:11ml | |
K = 1,000; M = 1,000,000 | ||
Measurement erro | ±1% (Newtonian liquid) | |
Repetitive error | ±0.5% (Newtonian liquid) | |
Show shear response / shear rate | standard configuration | |
Timing function | standard configuration | |
Real-time display Viscosity curve | Time-viscosity curve Temperature-viscosity curve (optional temperature probe) (Optional data processing software shows shear rate and viscosity curves) | |
Kinematic viscosity | Density of samples to be entered | |
Temperature measurement function | Standard temperature probe interface (optional temperature probe) | |
Automatic Scanning Function | Automatically scan and recommend the preferred combination of rotor and rotation speed | |
Maximum measurement range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | |
Self-built Measuring Procedures | Up to 30 groups (including rotor, speed, temperature, time, etc.) | |
Preservation of measurements | Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) | |
Put a seal on | Data, curve can be printed (standard print interface, need to buy printer) | |
Data output interface | RS232 | |
Thermostatic components | Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) | |
Working power supply | Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) | |
Outline dimension | 300 × 300 × 450(mm) |
Model | RVDV-1T | HADV-1T | MEHBDV-1T |
Control / display mode | 5-inch color touch screen | ||
Speed(r/min) | 0.3–100 infinitely variable speed , a total of 998 speed options | ||
Measuring range
| Rotor R2-R7:100-13M Rotor 21: 50-167K Rotor 27: 250-834K Rotor 2: 500-1.7M Rotor 29: 1K-3.3M | Rotor R2-R7:200–26M Rotor 21: 100-333K Rotor 27: 500-1.7K Rotor 28; 1K-3.3M Rotor 29: 2K-6.6M | Rotor R2-R7:800-104M URL: 51.2 - 2K Rotor 21: 400-1.3M Rotor 27: 2K-6.7M Rotor 28: 4K-13.3M Rotor 29: 8K-26.6M |
K = 1,000; M = 1,000,000 | |||
Rotor | R2- R7(6, standard) R1(apolegamy) Enhanced ultra-low viscosity adapter ULR (optional) Small sample adapters (rotor 21,27,28,29)(optional)) | ||
Sample dosage | Rotor R1-R7: 500ml ULR: 21ml Rotor 21: 7.8ml Rotor 27: 11.3ml Rotor 28: 12.6ml Rotor 29: 11.5ml | ||
Measurement erro | ±1% | ||
Repetitive error | ±0.5% | ||
Show shear response / shear rate | standard configuration | ||
Timing function | standard configuration | ||
Real-time display Viscosity curve | Time-viscosity curve Temperature-viscosity curve (optional temperature probe) (Optional data processing software shows shear rate and viscosity curves) | ||
Kinematic viscosity | Density of samples to be entered | ||
Temperature measurement function | Standard temperature probe interface (optional temperature probe) | ||
Automatic Scanning Function | Automatically scan and recommend the preferred combination of rotor and rotation speed | ||
Maximum measurement range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | ||
Self-built Measuring Procedures | Up to 30 groups (including rotor, speed, temperature, time, etc.) | ||
Preservation of measurements | Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) | ||
Put a seal on | Data, curve can be printed (standard print interface, need to buy printer) | ||
Data output interface | RS232 | ||
Thermostatic components | Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) | ||
Working power supply | Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) | ||
Outline dimension | 300 × 300 × 450(mm) |
Model | RVDV-2T | HADV-2T | HBDV-2T |
Control / display mode | 5-inch color touch screen | ||
Speed(r/min) | 0.1–200 infinitely variable speed , a total of 2000 speed options | ||
Measuring range
| Rotor R2-R7:100-40M Rotor 21: 25-500K Rotor 27: 125-2.5M Rotor 8:250-5M Rotor 29: 500-10M | Rotor R2-R7:200–80M Rotor 21: 50-1M Rotor 27:250-5M Rotor 28: 500-10M Rotor 29: 1K-20M | Rotor R2-R7:800-320M URL: 25.6 - 2K Rotor 21: 200-4M Rotor 27: 1K-20M Rotor 28: 2K-40M Rotor 29: 4K-80M |
K = 1,000; M = 1,000,000 | |||
Rotor | R2- R7(6, standard) R1(apolegamy) Enhanced ultra-low viscosity adapter ULR (optional) Small sample adapters (rotor 21,27,28,29)(optional)) | ||
Sample dosage | Rotor R1-R7: 500ml ULR: 21ml Rotor 21: 7.8ml Rotor 27: 11.3ml Rotor 28: 12.6ml Rotor 29: 11.5ml | ||
Measurement erro | ±1% | ||
Repetitive error | ±0.5% | ||
Show shear response / shear rate | standard configuration | ||
Timing function | standard configuration | ||
Real-time display Viscosity curve | Time-viscosity curve Temperature-viscosity curve (optional temperature probe) (Optional data processing software shows shear rate and viscosity curves) | ||
Kinematic viscosity | Density of samples to be entered | ||
Temperature measurement function | Standard temperature probe interface (optional temperature probe) | ||
Automatic Scanning Function | Automatically scan and recommend the preferred combination of rotor and rotation speed | ||
Maximum measurement range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | ||
Self-built Measuring Procedures | Up to 30 groups (including rotor, speed, temperature, time, etc.) | ||
Preservation of measurements | Up to 30 sets of data (including viscosity, temperature, rotor, speed, shear rate, shear stress, time, density, kinematic viscosity, etc.) | ||
Put a seal on | Data, curve can be printed (standard print interface, need to buy printer) | ||
Data output interface | RS232 | ||
Thermostatic components | Selections (including various viscometer special thermostatic tank, thermostatic cup, temperature control device, heating furnace) | ||
Working power supply | Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) | ||
Outline dimension | 300 × 300 × 450(mm) |