Atomic Absorption Spectrophotometer/AAS AA320N

Brand MesuLab
Product Category Analytical Instrument
Texture of Wood Hardware+plastic
Product Usage Atomic Absorption Photometer
Model AA320N
Contact us
E-mail
Product Details

Atomic Absorption Spectrophotometer

AAS AA320N

Common Features

1Build-in computer data processing and LCD display: stable and reliable with the functions of integral

holding, peakheight and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

2Stability: Double-beam system can automatically compensate the light source drift and wavelengthdrift

caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

3Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed

immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

4High precision of measurement: Gas path system is equipped with precision pressure stabilizing

and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.

5High energy optical path: A total reflection system is adopted to eliminate color difference in full

range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.

6Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys,

anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

7Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace

atomic absorption and hydride generation.

8Safe and reliable gas path system: Special devices of quick gas conversion and safety protection

can be used to analyze air-acetylene flame.

9Complete set of accessories: to be supplied with the instrument and ready for use after they are

purchased.


Specifications:

WL range

190-900nm

WL accuracy

≤±0.5nm

WL repeatability

≤0.3nm (single direction)

Spectrum bandwidth

0.2nm,0.4nm,0.7nm,1.4nm,2.4nm,5.0nm

Resolution

<40%

Base line stability

±0.004Abs/30min

Characteristic concentration of copper

≤0.04μg/ml/1%

Detection limit of copper

≤0.008μg/ml

Background calibration ability

Greater than30 times

RS232

including

Printer

optional

Power supply

220V 3A,50Hz

G.W.

160Kg/65Kg

Package Dimensions

1220x770x730mm (Main instrument)

800x400x900mm (Accessories)

Standard Accessories

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit

Burner unit

Dust cover

Water-separating gas filter

Titanium burner---10cm


Optional Accessories

Model GA3202 HGA graphite furnace system

Hydride generator

Hollow cathode lamp

Graphite tubes

Software

Recirculating cooling water system

Technical Specification


Model GA3202 HGA graphite furnace system

1Heating steps: 9 steps

2Temperature range (nominal Temperature):20℃~3000 C

3Slope heating time:0~999s

4Heating holding time:1s~999s (the sum of both time should be less than 999 seconds)

5Inert gas needed: argon, pressure of entry larger than 0.3Mpa

6Cooling water: tap water or cycling water, flow rate no less than 2L/min

7Output: LCD

8Gas pressure alarm, furnace overheated alarm

9Interface with Atomic absorption spectrophotometer,autosampler and RS232

10High-power temperature heating function(1000 C~2700 C)

11Test sample together with atom absorption equipment. Cd ≤1x10-12g;Cu ≤1x10-10g

12Working Conditions:

Power source:220V±22V,50Hz±1Hz, 3A

      220V±22V,50Hz±1Hz,30A

Power: 5.1kW for 220V on about2700℃

Ambient temperature:+10℃~+30℃

Relative humidity: less than 85%

Instrument rating power:7.2kW