Portable Multi-parameter Analyzer M310F-A/M310F/M310T/M510T-A/M510T

Brand MesuLab
Product Category Analytical Instrument
Texture of Wood Hardware+plastic
Product Usage Portable Multi-parameter Analyzer
Model M310F-A/M310F/M310T/M510T-A/M510T
Contact us
E-mail
Product Details

Portable Multi-parameter Analyzer

M310F-A/M310F/M310T/M510T-A/M510T


M310F-A Portable Multi-parameter Analyzer

GENERAL FEATURES

² LCD display screen, 3.5 inches.

² Multi-reading feature allows auto-read, timed-read and continuous-read.

² Automatic/Manual temperature compensation ensures accurate results.

² Auto-hold feature senses and locks the measurement endpoint.

² Data capacity of up to 500 sets for each parameter (GLP-compliant).

² Support for USB communication.

² Auto-power off feature effectively extends the battery service life.

² Reset feature automatically resumes all settings back to factory default options.

² IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.

pH

² 1-5 points calibration with Standard Recognition.

² Selectable pH buffer groups, including NIST, DIN, GB.

² Automatic electrode diagnosis with pH slope and offset display.

Ion

² 1-5 points calibration.

² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

² Measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

² 1-3 points calibration with Standard Recognition.

² Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.

² Temperature compensation type (none, linear, pure water).

PRODUCT SPECIFICATIONS

Model

M310F-A

Parameters

pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.)

pH

Range

-2.00 to 20.00 pH

Resolution

0.1, 0.01 pH

Accuracy

±0.02 pH

Calibration Points

Up to 5

Standard Customization

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1

Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00

Resolution

0.1, 0.01 pX

Accuracy

±0.02 pX

Calibration Points

Up to 5

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.5%

Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 500 mS/cm

Resolution

0.001 μS/cm minimum, various with range selection

Accuracy

±1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~20.00 MΩ·cm

Resolution

0.01 Ω·cm minimum

Accuracy

±1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, various with range selection

Accuracy

±1.0%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.2%

Temperature

Range

-5 to 110 ºC, 23 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.2

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

500 results each

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

Inputs

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600 sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

80×255×35 mm&400g (0.88 lb)


M310F Portable Multi-parameter Analyzer

GENERAL FEATURES

² LCD display screen, 3.5 inches.

² Multi-reading feature allows auto-read, timed-read and continuous-read.

² Automatic/Manual temperature compensation ensures accurate results.

² Auto-hold feature senses and locks the measurement endpoint.

² Data capacity of up to 500 sets for each parameter (GLP-compliant).

² Support for USB communication.

² Auto-power off feature effectively extends the battery service life.

² Reset feature automatically resumes all settings back to factory default options.

² IP65 waterproof. The portable meter is suitable for fields measurements and out

door measurements.

pH

² 1-5 points calibration with Standard Recognition.

² Selectable pH buffer groups, including NIST, DIN, GB.

² Automatic electrode diagnosis with pH slope and offset display.

Ion

² 1-5 points calibration.

² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

² Measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

² 1-3 points calibration with Standard Recognition.

² Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.

² Temperature compensation type (none, linear, pure water).

DO

² Support for air-saturated water or zero oxygen calibration.

² Auto barometric pressure compensation

² Manual Salinity Factor Correction

² Selectable pressure unit, including kPa, mbar, Torr, Atm.

PRODUCT SPECIFICATIONS

Model

M310F

Parameters

pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.00 to 20.00pH

Resolution

0.1, 0.01 pH

Accuracy

±0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1

Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00

Resolution

0.1, 0.01 pX

Accuracy

±0.01 pX

Calibration Points

Up to 5

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.5%

Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 500 mS/cm

Resolution

0.001 μS/cm minimum, various with range selection

Accuracy

±1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~20.00 MΩ·cm

Resolution

0.01 Ω·cm minimum

Accuracy

±1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, various with range selection

Accuracy

±1.0%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.2%

Dissolved

Oxygen Concentration

Range

0.00 to 50.00 mg/L

Resolution

0.01mg/L

Accuracy

±0.1mg/L

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 300.0)%

Resolution

0.1%

Accuracy

±10.0%

Temperature

Range

-5 to 110 ºC, 23 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.2

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

500 results each

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600 sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

80×255×35 mm

Weight

400g (0.88 lb)


M310T Portable Multi-parameter Analyzer

GENERAL FEATURES

² LCD display screen, 3.5 inches.

² Multi-reading feature allows auto-read, timed-read and continuous-read.

² Automatic/Manual temperature compensation ensures accurate results.

² Auto-hold feature senses and locks the measurement endpoint.

² Data capacity of up to 500 sets for each parameter (GLP-compliant).

² Support for USB communication.

² Auto-power off feature effectively extends the battery service life.

² Reset feature automatically resumes all settings back to factory default options.

² IP65 waterproof. The portable meter is suitable for fields measurements and

out door measurements.

pH

² 1-5 points calibration with Standard Recognition.

² Selectable pH buffer groups, including NIST, DIN, GB.

² Automatic electrode diagnosis with pH slope and offset display.

Ion

² 1-5 points calibration.

² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

² Measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

² 1-3 points calibration with Standard Recognition.

² Settable parameters, including cell constant, temperature compensation coefficient, and TDS factor.

² Temperature compensation type (none, linear, pure water).

DO

² Support for air-saturated water or zero oxygen calibration.

² Auto barometric pressure compensation

² Manual Salinity Factor Correction

² Selectable pressure unit, including kPa, mbar, Torr, Atm.

PRODUCT SPECIFICATIONS

Model

M310T

Parameters

pH/EC/ISE/DO/Temp. (mV/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.00 to 20.00pH

Resolution

0.1, 0.01 pH

Accuracy

±0.01 pH

Calibration Points

Up to 5

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

NIST, GB and DIN buffers

Slope Limit

Yes

mV

Range

-2000.0 to 2000.0 mV

Resolution

0.1 mV

Accuracy

±0.3 mV or ±0.1%

pX

Range

-2.00 to 20.00 pX

Resolution

0.1, 0.01 pX

Accuracy

±0.01 pX(±0.01 pX)

Calibration Points

Up to 5

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.5%

Calibration Points

Up to 5

Conductivity

Range

0.000 μS/cm to 1000 mS/cm

Resolution

0.001 μS/cm minimum, various with range selection

Accuracy

±1.0% FS

Reference Temperature

20, 25 ºC

Calibration Points

Up to 3

Standard Recognition

84μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω ·cm~20.00 MΩ ·cm

Resolution

0.01Ω ·cm minimum,

Accuracy

±1.0% FS

TDS

Range

0.00mg/L~300g/L

Resolution

0.01mg/L minimum, 3 significant digits

Accuracy

±1.0%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.2%

Dissolved

Oxygen Concentration

Sensor Type

0.00 to 50.00 mg/L

Range

0.00 to 50.00 mg/L

Resolution

0.01mg/L

Accuracy

±0.1mg/L

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 300.0)%

Resolution

0.10%

Accuracy

±2.0%

Temperature

Range

-5 to 110 ºC, 23.0 to 230 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.2

Measurement

Reading Mode

Auto-Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

PC, printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90 x 255 x 40 mm&500g (1.1 lb)



M510T-A Portable Multi-parameter Analyzer

GENERAL FEATURES

² Color High contrast LCD touchscreen, 4.3 inches.

² Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.

² Multi-reading feature allows auto-read, timed-read and continuous-read.

² Automatic/Manual temperature compensation ensures accurate results.

² Auto-hold feature senses and locks the measurement endpoint.

² Data Storage 1000 sets for each parameter (GLP-compliant).

² Data analysis feature helps user review, compare and recalculate results.

² Support for USB communication.

² Auto-power off feature effectively extends the battery service life.

² Reset feature automatically resumes all settings back to factory default options.

² IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.

pH

² 1-8 points calibration with Standard Recognition.

² Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.

² User-defined pH buffer or buffer group is supported.

² Automatic electrode diagnosis with pH slope and offset display.

Ion

² 1-6 points calibration.

² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

² Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

² 1-5 points calibration automatically recognizes the standard solutions.

² Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.

² Temperature compensation type (none, linear, pure water).


PRODUCT SPECIFICATIONS

Model

M510T-A

Parameters

pH/EC/ISE/Temp. (mV/ORP/pX/Resistivity/TDS/Sal.)

pH

Range

-2.000 to 20.000 pH

Resolution

0.1, 0.01, 0.001pH

Accuracy

±0.002 pH

Calibration Points

Up to 8

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

USA, NIST, MERK, JIS, GB and DIN buffers

Slope Limit

Yes

mV/ORP

Range

-2000.00 to 2000.00 mV

Resolution

0.1, 0.01 mV

Accuracy

±0.1 mV or ±0.03%

EH ORP Mode

Yes

ORP Calibration Points

1 custom point (relative mV)

pX

Range

-2.000 to 20.000 pX

Resolution

0.1, 0.01, 0.001 pX

Accuracy

±0.002 pX

Calibration Points

Up to 6

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.3%

Calibration Points

Up to 8

Conductivity

Range

0.000 μS/cm to 3000 mS/cm

Resolution

0.001 μS/cm minimum, various with range selection

Accuracy

±0.5% FS

Reference Temperature

5, 10, 15, 18, 20, 25 ºC

Calibration Points

Up to 5

Calibration Reminder

Yes

Standard Recognition

10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~100.00 MΩ·cm

Resolution

0.01 Ω·cm minimum

Accuracy

±0.5% FS

TDS

Range

0.000mg/L~1000g/L

Resolution

0.001mg/L minimum, changed with range

Accuracy

±0.5%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.1%

Temperature

Range

-10 to 135 ºC, 14 to 275 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.1

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC, scanner

Bluetooth

printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600 sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90×255×40 mm&500g (1.1 lb)


M510T Portable Multi-parameter Analyzer

GENERAL FEATURES

² Color High contrast LCD touchscreen, 4.3 inches.

² Intelligent operation system provides features including user management, calibration management, electrode management, method management, data management, Log Management and etc.

² Multi-reading feature allows auto-read, timed-read and continuous-read.

² Automatic/Manual temperature compensation ensures accurate results.

² Auto-hold feature senses and locks the measurement endpoint.

² Data Storage 1000 sets for each parameter (GLP-compliant).

² Data analysis feature helps user review, compare and recalculate results.

² Support for USB communication.

² Auto-power off feature effectively extends the battery service life.

² Reset feature automatically resumes all settings back to factory default options.

² IP65 waterproof. The portable meter is suitable for fields measurements and out door measurements.

pH

² 1-8 points calibration with Standard Recognition.

² Selectable pH buffer groups, including USA, NIST, DIN, GB, MERK, JIS.

² User-defined pH buffer or buffer group is supported.

² Automatic electrode diagnosis with pH slope and offset display.

Ion

² 1-6 points calibration.

² Selectable measurement unit, including μg/L, mg/L, g/L, mmol/L, pX, ppm, etc.

² Multi-measurement modes are supported, including Direct Reading mode, Standard Addition mode, Sample Addition mode and GRAN mode.

² Over 10 methods are built-in, including F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and etc., user-defined method is supported.

Conductivity

² 1-5 points calibration automatically recognizes the standard solutions.

² Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.

² Temperature compensation type (none, linear, pure water).

DO

² Support for air-saturated water or zero oxygen calibration.

² Auto barometric pressure compensation

² Manual Salinity Factor Correction

² Selectable pressure unit, including kPa, mbar, Torr, Atm.

PRODUCT SPECIFICATIONS

Model

M510T

Parameters

pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation)

pH

Range

-2.000 to 20.000 pH

Resolution

0.1, 0.01, 0.001pH

Accuracy

±0.002 pH

Calibration Points

Up to 8

Standard Customization

Yes

Calibration Reminder

Yes

Standard Recognition

USA, NIST, MERK, JIS, GB and DIN buffers

Slope Limit

Yes

mV/ORP

Range

-2000.00 to 2000.00 mV

Resolution

0.1, 0.01 mV

Accuracy

±0.1 mV or ±0.03%

EH ORP Mode

Yes

ORP Calibration Points

1 custom point (relative mV)

pX

Range

-2.000 to 20.000 pX

Resolution

0.1, 0.01, 0.001 pX

Accuracy

±0.002 pX

Calibration Points

Up to 6

ISE

Range

1E-9 to 9.999E9

Units

mol/L, mmol/L, g/L, mg/L, μg/L

Resolution

Up to 4 significant digits

Accuracy

±0.3%

Calibration Points

Up to 8

Conductivity

Range

0.000 μS/cm to 3000 mS/cm

Resolution

0.001 μS/cm minimum, various with range selection

Accuracy

±0.5% FS

Reference Temperature

5, 10, 15, 18, 20, 25 ºC

Calibration Points

Up to 5

Calibration Reminder

Yes

Standard Recognition

10μS/cm, 84μS/cm, 500μS/cm, 1413μS/cm, 12.88mS/cm

Resistivity

Range

5.00 Ω·cm~100.00 MΩ·cm

Resolution

0.01 Ω·cm minimum

Accuracy

±0.5% FS

TDS

Range

0.000mg/L~1000g/L

Resolution

0.001mg/L minimum, changed with range

Accuracy

±0.5%

Salinity

Range

(0.00~8.00)%

Resolution

0.01%

Accuracy

±0.1%

Dissolved

Oxygen Concentration

Sensor Type

Polarographic

Range

0.00 to 99.99 mg/L

Resolution

0.01mg/L

Accuracy

±0.3mg/L (0.00 to 20.00 mg/L);±10% (20.00 to 99.99 mg/L)

Calibration Reminder

Yes

Calibration Points

Air-saturated water or zero point

Barometric Compensation

Yes

Manual Salinity Factor Correction

Yes

Saturation

Range

(0.0 to 600.0)%

Resolution

0.10%

Accuracy

±10.0%

Temperature

Range

-10 to 135 ºC, 14 to 275 ºF

Unit

ºC, ºF

Resolution

0.1

Relative Accuracy

±0.1

Measurement

Reading Mode

Auto Read (Fast, Medium, Slow), Timed, Continuous

Reading Prompts

Reading, Stable, Locked

Temp. Compensation

ATC, MTC

Data management

Data Storage

1000 Groups

GLP Features

Yes

Inputs

pH Electrode

BNC(Q9)

DO with Temp. Probe

4-pin aviation connector

Conductivity with Temp. Probe

5-pin aviation connector

Outputs

USB

USB 2.0 flash memory device, PC, scanner

Bluetooth

printer

Display options

Backlight

Yes

Auto Shutdown

300, 600, 1200, 1800, 3600 sec., off

IP Rating

IP65

Date and Time

Yes

General

Power

Rechargeable Lithium battery, AC Adapter, 100-240V AC input, DC5V output

Dimensions

90×255×40 mm

Weight

500g (1.1 lb)