Karl Fischer KFT-20V
Karl Fischer Titrator KFT-40C/KFT-40VC/KFT-41C/KFT-41V/KFT-50C/KFT-50V/KFT-50VC
KFT-20V Karl Fischer Coulometer
GENERAL FEATURES
² LCD display screen.
² Generator cell with diaphragm.
² Selectable units including μg, mg, %, mg/L, g/L, etc.
² Settable parameters, includingmeasurement unit, polarization current, generator current, endpoint potential, stop criterion, etc.
² Data can be stored and easily transferred to printer via RS-232 communication interface.
² Reset feature automatically resumes all settings back to factory default options.
Includes
² JB-11 Stirrer
² Electrolysis electrode
² Work electrode
PRODUCT SPECIFICATIONS
Model | KFT-20V | |
Coulometric Ttration | Range | 10μg~20mg |
Polarization Current Accuracy | ±0.2μA | |
Working Current | 10mA, 20 mA, 50 mA, 100 mA | |
Working Current Accuracy | ±0.5% | |
Accuracy | ± (5%+3) μg | |
Repeatability | ≤3% | |
General | Power Supply | AC Adapter, 200-240V AC input |
Dimensions | 300×235×100 mm/2 kg | |
Dimensions (Carton) | 370×305×330 mm/5 kg | |
KFT-40C Karl Fischer Titrator
GENERAL FEATURES
² LCD display screen.
² Support KF Titration Mode and Titer Detection Mode.
² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
² Selectable units including mg, mg/L, %, ppm, etc.
² Settable parameters, includingmeasurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion, etc.
² Store up to 200 titration data sets (GLP-compliant).
² Data can be easily transferred to printer via RS-232 commnication interface.
² Reset feature automatically resumes all settings back to factory default options.
Includes
² Measuring electrode
² 10mL burette
² Volumetric titration cell
PRODUCT SPECIFICATIONS
Model | KFT-40C | |
Volumetric Titration | Range | 0.1mg~250mg |
Resolution | 0.1mg | |
Working Current | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ≤0.5% | |
General | Power Supply | AC Adapter, 100-240 V AC input |
Dimensions(meter) | 340×400×400 mm/10kg | |
Dimensions (Carton) | 550×500×500 mm/13 kg | |
KFT-40VC Karl Fischer Titrator
GENERAL FEATURES
² LCD display screen.
² Titration methods, curves and results are displayed in detail.
² Volumetric KF Titration and Coulometric KF Titration are supported.
² Data analysis feature helps user review and compare results.
² Data can be easily transferred to printer via RS-232 communication interface.
² Reset feature automatically resumes all settings back to factory default options.
Volumetric Karl Fischer Titration
² Support KF Titration Mode and Titer Detection Mode.
² Features of auto-filling, auto-purging and auto-mixing of the reagents ensure safe handling of Karl Fischer chemicals.
² Automatic/manual background drift correction ensures accurate results.
² Selectable units including mg, mg/L, %, ppm, etc.
² Settable parameters, includingmeasurement unit, polarization current, stirring rate, titration rate, stop volume, endpoint potential, stop criterion, etc.
² Store up to 200 titration data sets (GLP-compliant).
Coulometric Karl Fischer Titration
² Generator cell with diaphragm.
² Automatic/manual background drift correction ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² Settable parameters, includingmeasurement unit, polarization current, stirring rate, generator current, endpoint potential, stop criterion, etc.
² Store up to 200 titration data sets (GLP-compliant).
Includes
² External device
² Electrolysis electrode
² Measuring electrode
² 10mL Burette
² Volumetric titration cell
² Coulometric titration cell
PRODUCT SPECIFICATIONS
Model | KFT-40VC | |
Volumetric Titration | Range | (0.1mg~250)mg |
Polarization Current Accuracy | 1μA±0.2μA; 50μA±10μA | |
Repeatability | ≤0.5% | |
Coulometric Titration | Range | 10μg~20mg |
Polarization Current Accuracy | ±0.2μA | |
Working Current | 1, 1.86, 5,10 μg(H2O)/s for 10.72mA, 20 mA, 53.61mA, 107.2 mA | |
Working Current Accuracy | ±0.5% | |
Accuracy | ± (5%+3) μg | |
Repeatability | ≤3% | |
General | Power Supply | AC Adapter,100-240 V AC input |
Dimensions(meter) | 240×360×400mm/4kg | |
Dimensions (Carton) | 550×500×500mm/13kg | |
KFT-41C Karl Fischer Titrator (2025)
GENERAL FEATURES
² Color High contrast LCD touchscreen, 7.0 inches.
² Coulometric KF Titration.
² Support oven sampling method, to meet the gas, solid, liquid in the constant moisture, trace moisture measurement.
Coulometric Karl Fischer Titration
² Auto Titration Method, Oven Titration Method, Oven Blank, and Coefficient correction Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to drain solution and feed solvent, ensure safe handling of Karl Fischer chemicals.
Data management
² Auto/manual drift adjust ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² User password management.
² Store up to 200 titration data sets (GLP-compliant).
² RS-232 communication for print and the print format can be alternate.
² USB communication for PC software.
² USB drive for data export with CSV format.
² It needs GMP software to implement GMP management functions.
Includes
² Solvent manager
² Coulometric vessel
² Measuring electrode
² Generator electrode
PRODUCT SPECIFICATIONS
Model | KFT-41C | |
Principle | Karl Fischer Coulometric Titration | |
Water | Range | 10.0μg~200mg |
Resolution | 0.1μg | |
Unit | μg, mg, %, ppm, μg/mL, mg/L | |
Repeatability | ≤1% | |
mV Range | (0~2000)mV | |
mV Resolution | 0.1mV | |
Polarization Current Accuracy | ±3% | |
Polarization Current Fluctuation | ±2.5%/30min | |
Working Current Accuracy | ±0.5% | |
Working Current Fluctuation | ±0.2%/10min | |
Power Supply | AC100-240V, 47-63Hz | |
Dimensions(meter) | 240×360×400mm/4kg | |
Dimensions (Carton) | 550×500×500mm/13kg | |
KFT-41V Karl Fischer Titrator (2025)
GENERAL FEATURES
² Color High contrast LCD touchscreen, 7.0 inches.
² Volumetric KF Titration.
² Support oven sampling method, to meet the gas, solid, liquid in the constant moisture, trace moisture measurement.
Volumetric Karl Fischer Titration
Auto Titration Method, KF Titer Determination Method, Oven Titration Method and Oven Blank Titration Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to fill titrant, drain solution, feed solvent, mix titrant and clean burette, ensure safe handling of Karl Fischer chemicals.
Data management
² Auto/manual drift adjust ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² User password management.
² Store up to 200 titration data sets (GLP-compliant).
² RS-232 communication for print and the print format can be alternate.
² USB communication for PC software.
² USB drive for data export with CSV format.
² It needs GMP software to implement GMP management functions.
Includes
² Solvent manager
² 10mL burette
² Volumetric vessel
² Measuring electrode
Model | KFT-41V | |
Principle | Karl Fischer Volumetric Titration | |
Water | Range | (0.1~250.0)mg |
Resolution | 1μg | |
Unit | μg, mg, %, ppm, μg/L, mg/L | |
Repeatability | ≤0.5% | |
mV Range | (0~2000)mV | |
mV Resolution | 1mV | |
Polarization Current Range | ±3% | |
Polarization Current Accuracy | ±2.5%/30min | |
Power Supply | AC100-240V, 47-63Hz | |
Dimensions(meter) | 240×360×400mm/4kg | |
Dimensions (Carton) | 550×500×500mm/13kg | |
KFT-50C Karl Fischer Titrator (2025)
GENERAL FEATURES
² Color High contrast LCD touchscreen, 7.0 inches.
² Coulometric KF Titration.
² Support oven sampling method, to meet the gas, solid, liquid in the constant moisture, trace moisture measurement.
Coulometric Karl Fischer Titration
² Intelligent operation system provides features including user management, method management, sensor management, data management and GMP management etc.
² Auto Titration Method, Oven Titration Method, Oven Blank, and Coefficient correction Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to drain solution and feed solvent, ensure safe handling of Karl Fischer chemicals.
Data management
² Auto/manual drift adjust ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² User three-level authority management and password management.
² Support for GMP management, the GMP logs achieve the tracking and analysis of the the data.
² Store up to 2000 titration data sets (GLP-compliant).
² RS-232 communication for print and the print format can be alternate.
² USB communication for PC software.
² USB drive for method export and import.
² USB drive for data export with CSV or PDF format.
² Support for printer, barcode scanner, oven and balance(specific model).
² It needs GMP software to implement GMP management functions.
Includes
² Solvent manager
² Coulometric vessel
² Measuring electrode
² Generator electrode
PRODUCT SPECIFICATIONS
Model | KFT-50C | |
Principle | Karl Fischer Coulometric Titration | |
Water | Range | 3.0μg~200mg |
Resolution | 0.1μg | |
Unit | μg, mg, %, ppm, μg/mL, mg/L | |
Repeatability | ≤0.3% | |
mV Range | (0~2000)mV | |
mV Resolution | 0.1mV | |
Polarization Current Range | (1~200) μA | |
Polarization Current Accuracy | ±3% | |
Polarization Current Fluctuation | ±2.5%/30min | |
Working Current Accuracy | ±0.5% | |
Working Current Fluctuation | ±0.2%/10min | |
Power Supply | AC100-240V, 47-63Hz | |
Dimensions(meter) | 240×360×400mm/4kg | |
Dimensions (Carton) | 550×500×500mm/13kg | |
KFT-50V Karl Fischer Titrator (2025)
GENERAL FEATURES
² Color High contrast LCD touchscreen, 7.0 inches.
² Volumetric KF Titration.
² Support oven sampling method, to meet the gas, solid, liquid in the constant moisture, trace moisture measurement.
Volumetric Karl Fischer Titration
² Intelligent operation system provides features including user management, method management, sensor management, titrant management, data management and GMP management etc.
² Auto Titration Method, KF Titer Determination Method, Oven Titration Method and Oven Blank Titration Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to fill titrant, drain solution, feed solvent, mix titrant and clean burette, ensure safe handling of Karl Fischer chemicals.
Data management
² Auto/manual drift adjust ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² User three-level authority management and password management.
² Support for GMP management, the GMP logs achieve the tracking and analysis of the the data.
² Store up to 2000 titration data sets (GLP-compliant).
² RS-232 communication for print and the print format can be alternate.
² USB communication for PC software.
² USB drive for method export and import.
² USB drive for data export with CSV or PDF format.
² Support for printer, barcode scanner, oven and balance(specific model).
² It needs GMP software to implement GMP management functions.
Includes
² Solvent manager
² 10mL burette
² Volumetric vessel
² Measuring electrode
Model | KFT-50V | |
Principle | Karl Fischer Volumetric Titration | |
Water | Range | 100 μg~250.0mg |
Resolution | 1μg | |
Unit | μg, mg, %, ppm, μg/L, mg/L | |
Repeatability | ≤0.3% | |
mV Range | (0~2000)mV | |
mV Resolution | 0.1mV | |
Polarization Current Range | (1~200) μA | |
Polarization Current Accuracy | ±3% | |
Polarization Current Fluctuation | ±2.5%/30min | |
Power Supply | AC100-240V, 47-63Hz | |
Dimensions(meter) | 240×360×400mm/4kg | |
Dimensions (Carton) | 550×500×500mm/13kg | |
KFT-50VC Karl Fischer Titrator (2025)
GENERAL FEATURES
² Color High contrast LCD touchscreen, 7.0 inches.
² Volumetric KF Titration and Coulometric KF Titration are supported.
² Support oven sampling method, to meet the gas, solid, liquid in the constant moisture, trace moisture measurement.
Volumetric Karl Fischer Titration
² Intelligent operation system provides features including user management, method management, sensor management, titrant management, data management and GMP management etc.
² Auto Titration Method, KF Titer Determination Method, Oven Titration Method and Oven Blank Titration Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to fill titrant, drain solution, feed solvent, mix titrant and clean burette, ensure safe handling of Karl Fischer chemicals.
Coulometric Karl Fischer Titration
² Intelligent operation system provides features including user management, method management, sensor management, data management and GMP management etc.
² Auto Titration Method, Oven Titration Method, Oven Blank, and Coefficient correction Method.
² The solvent manager adopts anti-leakage liquid and anti-pour design of waste liquid bottle, supports to drain solution and feed solvent, ensure safe handling of Karl Fischer chemicals.
Data management
² Auto/manual drift adjust ensures accurate results.
² Selectable units including μg, mg, %, ppm, mg/L and μg/mL.
² User three-level authority management and password management.
² Support for GMP management, the GMP logs achieve the tracking and analysis of the the data.
² Store up to 2000 titration data sets for volumetric and coulometric titration (GLP-compliant).
² RS-232 communication for print and the print format can be alternate.
² USB communication for PC software.
² USB drive for method export and import.
² USB drive for data export with CSV or PDF format.
² Support for printer, barcode scanner, oven and balance(specific model).
² It needs GMP software to implement GMP management functions.
Includes
² Solvent manager
² 10mL burette
² Volumetric vessel
² CDY-4 Measuring electrode
² Coulometric vessel
² CDY-4 Measuring electrode
² CDJ-3 Generator electrode
PRODUCT SPECIFICATIONS
Model | KFT-50VC | ||
Principle | Karl Fischer Volumetric Titration | Karl Fischer Coulometric Titration | |
Water | Range | 100 μg~250.0mg | 3.0μg~200mg |
Resolution | 1μg | 0.1μg | |
Unit | μg, mg, %, ppm, μg/L, mg/L | μg, mg, %, ppm, μg/mL, mg/L | |
Repeatability | ≤0.3% | ≤0.3% | |
mV Range | (0~2000)mV | (0~2000)mV | |
mV Resolution | 0.1mV | 0.1mV | |
Polarization Current Range | (1~200) μA | (1~200) μA | |
Polarization Current Accuracy | ±3% | ±3% | |
Polarization Current Fluctuation | ±2.5%/30min | ±2.5%/30min | |
Working Current Accuracy | / | ±0.5% | |
Working Current Fluctuation | / | ±0.2%/10min | |
Power Supply | AC100-240V, 47-63Hz | ||
Dimensions(meter) | 240×360×400mm/4kg | ||
Dimensions (Carton) | 550×500×500mm/13kg | ||
Karl Fischer Titrator,kf titrator,karl fischer moisture titrator,kf moisture analyzer,karl fischer titration instrument,automated karl fischer titrator,coulometric karl fischer titrator,volumetric karl fischer titrator,kf moisture tester,karl fischer moisture analyzer,kf titration equipment,laboratory karl fischer titrator,auto karl fischer titrator,kf water content analyzer,karl fischer water determination instrument,kf titration system,automated moisture titrator,karl fischer water content tester,lab kf titrator,kf water testing device,karl fischer titration apparatus,moisture titration analyzer,coulomb karl fischer titrator,volumetric kf titrator,water content titrator,industrial karl fischer titrator,kf moisture detection equipment,karl fischer moisture testing instrument